Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables

Application

Marine fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore

units, suitable for use in power and control applications where fire integrity is essential.

Standards

BS 7917

IEC 60331-31 Fire resistant

IEC 60332-3A Flame retardant

IEC 60754-1; IEC 60754-2 Corrosivity

IEC 61034-2 Smoke density

Cold bend and impact (-40°C) (on request)

CSA C22.2 No. 38-95 (on request)

Construction

nek 606 marine cable

Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.

Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.

Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.

Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered

upon request.

Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen

thermosetting compound SW2 according to BS 7655 2.6.

Mechanical and Thermal Properties

Minimum Internal Bending Radius: 6×OD

Temperature Range: -40℃ ~ +90℃

Dimensions and Weight

Single core cables

Construction
No. of cores×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
1×4 1.0 1.0 6.7 8.0 0.3 1.1 10.2 12.1 245
1×6 1.0 1.0 7.2 8.5 0.3 1.1 10.8 12.6 275
1×10 1.0 1.0 8.1 9.5 0.3 1.2 11.9 13.8 355
1×16 1.0 1.1 9.3 10.7 0.3 1.2 13.1 15.0 440
1×25 1.2 1.2 11.5 13.2 0.3 1.3 15.4 17.7 600
1×35 1.2 1.2 12.3 14.1 0.3 1.4 16.5 18.8 720
1×50 1.4 1.3 14.1 15.9 0.3 1.4 18.2 20.6 910
1×70 1.4 1.3 15.8 17.8 0.3 1.5 20.2 23.0 1170
1×95 1.6 1.4 18.1 20.2 0.3 1.6 22.6 25.6 1510
1×120 1.6 1.5 20.0 22.4 0.3 1.7 24.7 27.7 1830
1×150 1.8 1.6 22.0 24.6 0.3 1.8 26.9 30.1 2160
1×185 2.0 1.7 24.4 27.0 0.45 1.9 30.2 33.9 2790
1×240 2.2 1.8 27.5 30.3 0.45 2.0 33.5 37.3 3530
1×300 2.4 1.9 30.4 33.6 0.45 2.1 36.6 40.5 4280

Multicore cables


Construction
No. of cores×Cross section

mm²

Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
2×1.5 0.8 1.1 9.0 10.4 0.3 1.2 12.7 14.7 310
2×2.5 0.8 1.1 9.8 11.4 0.3 1.2 13.6 15.5 355
2×4 1.0 1.2 11.8 13.5 0.3 1.3 15.7 18.0 475
2×6 1.0 1.2 12.9 14.6 0.3 1.4 17.0 19.3 580
2×10 1.0 1.3 14.9 16.8 0.3 1.4 19.0 21.4 750
2×16 1.0 1.4 17.1 19.1 0.3 1.5 21.4 24.3 980
2×25 1.2 1.5 21.2 23.7 0.3 1.7 25.9 29.0 1380
2×35 1.2 1.6 23.1 25.7 0.3 1.8 28.0 31.2 1710
2×50 1.4 1.7 26.5 29.2 0.45 2.0 32.5 36.3 2370
2×70 1.4 1.9 30.3 33.5 0.45 2.1 36.5 40.5 3100
2×95 1.6 2.1 34.9 38.2 0.45 2.3 41.4 46.0 4020
2×120 1.6 2.2 38.4 42.2 0.45 2.5 45.4 50.1 4870
3×1.5 0.8 1.1 9.6 11.0 0.3 1.2 13.3 15.3 345
3×2.5 0.8 1.1 10.4 12.1 0.3 1.3 14.4 16.4 405
3×4 1.0 1.2 12.6 14.3 0.3 1.3 16.5 18.8 540
3×6 1.0 1.2 13.8 15.5 0.3 1.4 17.9 20.2 660
3×10 1.0 1.3 15.9 17.8 0.3 1.5 20.2 23.0 910
3×16 1.0 1.4 18.2 20.3 0.3 1.6 22.8 25.7 1200
3×25 1.2 1.6 22.9 25.4 0.3 1.8 27.8 30.9 1760
3×35 1.2 1.7 24.9 27.6 0.45 1.9 30.7 34.4 2260
3×50 1.4 1.8 28.5 31.3 0.45 2.0 34.5 38.4 2880
3×70 1.4 2.0 32.7 35.9 0.45 2.2 39.0 43.5 3800
3×95 1.6 2.2 37.5 41.0 0.45 2.4 44.3 48.9 4890
3×120 1.6 2.3 41.3 45.3 0.45 2.6 48.5 53.7 6070
3×150 1.8 2.5 45.8 49.9 0.45 2.8 53.3 58.7 7270
3×185 2.0 2.7 50.9 55.5 0.45 3.0 58.8 64.9 8970
3×240 2.2 2.9 57.5 62.4 0.45 3.2 65.8 72.2 1350

Construction
No. of cores×Cross section

mm²

Nominal Insulation Thickness
mm
Nominal Inner Sheath Thickness
mm
Minimum Diameter Over Inner Sheath
mm
Maximum Diameter Over Inner Sheath
mm
Nominal Armour Wire Diameter
mm
Nominal Outer Sheath Thickness
mm
Minimum Overall Diameter
mm
Maximum Overall Diameter
mm
Approx. Weight
kg/km
4×1.5 0.8 1.1 10.5 12.1 0.3 1.3 14.4 16.4 395
4×2.5 0.8 1.1 11.4 13.1 0.3 1.3 15.4 17.6 465
4×4 1.0 1.2 13.8 15.6 0.3 1.4 17.9 20.3 640
4×6 1.0 1.3 15.3 17.3 0.3 1.5 19.6 22.5 790
4×10 1.0 1.4 17.7 19.7 0.3 1.6 22.2 25.1 1070
4×16 1.0 1.5 20.3 22.8 0.3 1.7 25.0 28.1 1460
4×25 1.2 1.7 25.5 28.1 0.45 1.9 31.3 35.0 2140
4×35 1.2 1.8 27.7 30.5 0.45 2.0 33.7 37.5 2670
4×50 1.4 1.9 31.8 35.0 0.45 2.2 38.1 42.1 3630
4×70 1.4 2.1 36.3 39.7 0.45 2.4 43.1 47.7 4740
4×95 1.6 2.3 41.7 45.7 0.45 2.6 48.9 54.1 6290
4×120 1.6 2.5 46.2 50.3 0.45 2.8 53.7 59.2 7670
5×1.5 0.8 1.1 11.4 13.1 0.3 1.3 15.4 17.6 455
7×1.5 0.8 1.2 12.6 14.4 0.3 1.3 16.6 18.9 530
12×1.5 0.8 1.3 16.8 18.8 0.3 1.5 21.2 24.0 790
19×1.5 0.8 1.4 19.9 22.4 0.3 1.6 24.4 27.5 1080
27×1.5 0.8 1.6 24.3 26.9 0.3 1.8 29.2 32.8 1460
37×1.5 0.8 1.7 27.4 30.4 0.45 1.9 33.2 37.0 1990
5×2.5 0.8 1.2 12.7 14.4 0.3 1.3 16.6 18.9 560
7×2.5 0.8 1.2 13.9 15.6 0.3 1.4 18.0 20.3 650
12×2.5 0.8 1.4 18.7 20.8 0.3 1.6 23.2 26.2 970
19×2.5 0.8 1.5 22.1 24.7 0.3 1.7 26.8 30.0 1360